A-255 B. CT

J. Vilar | Saturday, March 9, 10:30 – 12:00 / Room A

Interpretation of chest images is fraught with errors. Confusing images may occur in chest CT and conventional radiography. Understanding the cause of the error and using some “ tricks” the radiologist may overcome these situations. Three aspects that may be of useful are: Gravity, Space and Time. Gravity may help the radiologist by using simple manoeuvres such as prone or lateral decubitus. Space relates to the location of the lesion. Upper or lower lobe locations are associated with certain pathologies. Time lapse is a major factor that may influence our diagnosis. Previous studies are essential. Fast growth or reduction of a lesion usually is associated with non-neoplastic disorders. Follow-up in acutely ill patients may be of great value and well as in lesions in oncologic patients. The lecture will present cases of variable difficulty where using these simple “tricks” the diagnostic problem can be solved.

01
Mar 2014
POSTED BY
DISCUSSION 0 Comments

ECR 2013 Rec: A. Diagnosis #RC1601a #A545

ECR2013Rec_Blog_Cover_A545_RC1601a

A-545 A. Diagnosis

M. Krokidis | Monday, March 11, 08:30 – 10:00 / Room E1

Oesophageal cancer is the sixth leading cause of death from cancer worldwide. More than 90 % of oesophageal cancers are either squamous-cell carcinomas or adenocarcinomas. Approximately, three quarters of all adenocarcinomas are found in the distal oesophagus, whereas squamous cell carcinomas are more evenly distributed between the middle and lower third. The cervical oesophagus is an uncommon site of disease. The pathogenesis of oesophageal cancer remains unclear. At the time of the diagnosis of oesophageal cancer, more than 50 % of patients have either unresectable tumours or visible metastases on imaging. The most common symptom of presentation is dysphagia which is present in >70% of the cases; odynophagia may also be present in a smaller percentage of patients. The patients are usually presented also with significant weight loss which appears to be also an important prognostic factor of the outcome of the disease. Diagnosis is based on the findings of a contrast swallow- which is usually the first exam to be performed; oesophageal cancer may present as polypoid, infiltrative, varicoid, or ulcerative lesions. Endoscopy usually confirms the findings of the swallow study, revealing the presence of a mass and offering the possibility of taking biopsy samples. Endoscopic ultrasound is the imaging method that is used for local staging and CT and PET-CT are used to determine the presence of metastatic disease. In case of presence of enlarged lymphnodes, fine needle aspiration or even open biopsy may be performed.

28
Feb 2014
POSTED BY
DISCUSSION 0 Comments

ECR 2013 Rec: High-resolution computed tomography (HRCT) of the lungs in brain dead pigs: a feasibility study #SS204 #B0169

ECR2013Rec_Blog_Cover_B0169_SS204

B-0169 High-resolution computed tomography (HRCT) of the lungs in brain dead pigs: a feasibility study

G. Bozovic, S. Steen, T. Sjöberg, C. Schaefer-Prokop, J. Verschakelen, Q. Liao, R. Siemund, I. Björkman-Burtscher | Thursday, March 7, 14:00 – 15:30 / Room D1

Purpose: Brain death has adverse effects on lung perfusion and ventilation with possible damage of lung parenchyma pre-transplantation. We wanted to assess brain dead subjects treated with a new drug regime with HRCT as a pre-transplant work-up.
Methods and Materials: Eleven pigs were decapitated (DC) assuring brain death, attached to ventilator and treated with a new drug regime optimising circulation thereby preventing lung edema. Thirteen non-decapitated pigs (N-DC) attached to ventilator, supported with conventional treatment served as controls. All were monitored 24h and thereafter examined with chest HRCT. Images were analysed by two radiologists using a pre-defined questionnaire assessing parenchymal and airway changes. In consensus, an overall conclusion inferred presence of edema, infection/atelectasis or airway pathology. Severity was estimated with a subjective scale.
Results: After 24h there were no significant differences between the groups regarding mean arterial pressure (MAP), arterial oxygen/fraction of inspired oxygen (PaO2/FiO2), amount of infused fluid, urine production or clinical signs of edema. Both groups showed parenchymal changes in a comparable extent (consolidation in 6/11 (DC) and 10/13 (N-DC) and GGO in 6/11 (DC) and 9/13 (N-DC), respectively). Overall conclusion appraised the presence of oedema in 2/11 (DC) but none of the N-DC pigs, signs of old/ recent infection in 6/11 (DC) and 7/13 (N-DC) and possible hypersensitive pneumonitis in 1/13 (N-DC).
Conclusion: After 24h, there were no significant differences in clinical and imaging findings between the groups supporting the successful hemodynamic optimising with the new drug regime. HRCT allows evaluation of pre-transplant lungs.

27
Feb 2014
POSTED BY
DISCUSSION 0 Comments

ECR 2013 Rec: Detection of HCC and liver metastases with BR14: final results of a multicentre phase IIA study #SS201b #B0232

ECR2013Rec_Blog_Cover_B0232_SS201b

B-0232 Detection of HCC and liver metastases with BR14: final results of a multicentre phase IIA study

J. Hohmann, A. Müller, J. Skrok, K.-J. Wolf, A. Martegani, C.F. Dietrich, T. Albrecht | Thursday, March 7, 14:00 – 15:30 / Room I/K

Purpose: The study was primarily designed to find the optimal dose range of BR14 to detect malignant focal liver lesions. Secondary objectives were the evaluation of the safety profile and comparison with contrast-enhanced MRI (CE MRI).
Methods and Materials: 25 patients (9f, 16m, mean age: 66y) with known HCC or liver metastases were examined in three centres during a time period of three months. Each patient underwent a baseline and at least three contrast-enhanced US (CEUS) with ascending dose levels (0.25ml, 1.0ml, 4.0ml) of BR14. CE MRI was done 4 weeks prior or post-study examination. Lesions were recorded in on a liver map, with respect to localisation, size and suggested lesion type. Examination quality was documented and safety parameters were assessed.
Results: The number of lesions detected with BR14 CEUS increased with dose, while the number of missed lesions and the lesion size decreased. Despite the increasing contrast enhancement no other image quality parameter showed a substantial difference. No significant changes were found for the analysed safety parameters and no serious adverse events were reported.
Conclusion: We finally conclude that the recommended dose level of BR14 is between 1.0 ml and 4.0 ml for which the lesion detection was comparable to the CE MRI. In addition, we found a higher number of especially small lesions with higher doses of BR14 which might be due to a higher sensitivity of CEUS for the detection of liver metastases. However, this is an interesting and debatable finding.

ECR 2013 Rec: Bon appétit! Starters”: cystic fibrosis, pneumonia and pulmonary embolism #SF4a #A083

ECR2013Rec_Blog_Cover_A083_SF4a

A-083 Bon appétit! Starters”: cystic fibrosis, pneumonia and pulmonary embolism

M.U. Puderbach | Friday, March 8, 08:30 – 10:00 / Room F2

CF: MRI is comparable to CT with regard to the detection of relevant morphological changes in the CF lung. Compared to CT, the strength of MRI is the additional assessment of “function”, i.e. perfusion, pulmonary haemodynamics and ventilation. In CF, regional ventilatory defects cause changes in regional lung perfusion due to the hypoxic vasoconstriction response or tissue destruction. Using dynamic contrast-enhanced MRI, these perfusion changes can be assessed. Pulmonary embolism: The current imaging reference technique in evaluation of acute pulmonary embolism is helical computed tomography. To be competitive with CT, an abbreviated MR protocol focusing on lung vessel imaging and lung perfusion may be accomplished within 15 min in-room time. As a first step, a steady-state GRE sequence acquired in two or three planes during free breathing enables a non-contrast-enhanced detection of large central emboli. As a second step, the protocol continues with the contrast-enhanced steps including first pass perfusion imaging, high spatial resolution contrast-enhanced (CE) MRA and a final acquisition with a volumetric interpolated 3D FLASH sequence in transverse orientation. Pneumonia: The potential of MRI to replace chest radiography, particularly in children, was already investigated several years ago. The experience from this work may be considered valid for the suggested protocols for 1.5-T scanners since image quality has significantly improved. Therefore, T2-weighted fat-suppressed as well as dynamic contrast-enhanced T1-GRE sequences are applied with a slice thickness between 5 and 6 mm. Disease entities encompassing community-acquired pneumonia, empyema, fungal infections and chronic bronchitis are detectable.

24
Feb 2014
POSTED BY
DISCUSSION 0 Comments

ECR 2013 Rec: Can non-invasive techniques as CTA and MRA replace catheter angio for diagnostic work-up? #SF8a #A205

ECR2013Rec_Blog_Cover_A205_SF8a

A-205 Can non-invasive techniques as CTA and MRA replace catheter angio for diagnostic work-up?

L. van den Hauwe, M. Voormolen, T. van der Zijden, R. Salgado, J. Van Goethem, P.M. Parizel | Saturday, March 9, 08:30 – 10:00 / Room B

Although catheter angiography remains the gold standard for cerebrovascular imaging, in recent years, it has been replaced to some extent by less-invasive techniques, such as CTA, MRA, and ultrasound. Some of these techniques allow for cerebrovascular imaging without exposure to ionizing radiation, and/or without requiring an exogenous contrast agent that could cause nephrotoxicity, allergic reaction, or other adverse effects. Moreover, all of these techniques avoid the extra time, expense, and possibility of complications that are associated with arterial catheterization. Ongoing developments in CT- and MR-based angiography continue to improve the effectiveness of these techniques, and to expand the clinical roles that they can fulfill. Nowadays, these noninvasive techniques not only provide images with high spatial resolution, but also offer time-resolved images, in which arterial and venous phases can be distinguished, and can provide selective visualization of vessels supplied by a single supplying artery. This presentation will review the latest developments in CT- and MR-based cerebral angiography, and illustrate the use of these CT- and MR-techniques in the diagnosis of cerebral aneurysms and vascular malformations.

22
Feb 2014
POSTED BY
DISCUSSION 0 Comments

ECR 2013 Rec: Role of imaging in personalised therapy monitoring #pc11 #a329

ECR2013Rec_Blog_Cover_A329_PC11

A-329 Role of imaging in personalised therapy monitoring

A.R. Padhani | Saturday, March 9, 16:00 – 17:30 / Room F2

Many imaging biomarkers have emerged which individually or collectively provide unique information on tumour behaviour including response to treatment. There are several requirements that must be met before imaging biomarker(s) can be considered as being able to direct a person’s management. First, the biomarker should have a known biologic basis with a recognised method for quantification and to be adequately validated. With regard to the latter, it is important that the biomarker reports on/measures biologically meaningful cellular/tissue process such as reporting on cell death, on angiogenesis, proliferation and metabolic shutdown NOT simply conveying information on receptor occupancy or down regulation of pathways that may or may not be important. Data acquisition procedures should have been optimised and the test’s performance should have been established. The level of change in the imaging biomarker that can be considered as real should be known (that is, the measurement error). Reproducibility needs to have been determined by appropriately powered test-retest studies. Imaging biomarkers can only be useful if they can detect biologically meaningful effects directly related to treatments (that is, magnitude of biological effects detected must be greater than the reproducibility/measurement error) at appropriate time points to be able to effect patient management. Finally, it must be know how much therapy-induced change is meaningful in terms of patient benefit in terms of hard clinical endpoints such as surgical resectability, organ preservation, progression free and overall survival, etc. These aspects will be considered in detail using practical examples.

ECR 2013 Rec: MR spectroscopy in mild and moderate cognitive impairment as illness outcome predictor: preliminary experience #SS611 #B0403

ECR2013Rec_Blog_Cover_B0403_SS611

B-0403 MR spectroscopy in mild and moderate cognitive impairment as illness outcome predictor: preliminary experience

J. Forner Giner, A. Alberich-Bayarri, G. Garcia Marti, A. Pomar-Nadal, J. Rayón-Aledo, L. Martí-Bonmatí | Friday, March 8, 14:00 – 15:30 / Room B

Purpose: To evaluate Alzheimer’s disease premature diagnosis based on spectroscopy MRI.
Methods and Materials: We carried out a prospective study on 178 patients (116 women and 62 men) whose ages ranged 27 to 68 years (mean age 65 ± 12). Every patient presented mild or moderate cognitive impairment according to Reisberg score (3-4 grade). Standard brain MR and spectroscopy brain MR were performed using a 3 T intensity MRI device (Archieva TX, Philips Healthcare, Best, The Netherlands). Spectroscopy MR was focused in posterior parietal and frontal lobes gray substance using a unique volume (20 x 20 x 15 mm) and two different echo-times, TE (32 and 136). Morphology and volume of temporal lobes were evaluated through FLAIR coronal images which were used to quantify temporal horn width and so classify patients in four groups. JMRUI (Java Magnetic Resonance User Interface) was used to calculate quantitative parameters in MR spectroscopy. MR was used to measure: calculation of NAA (N-acetyl aspartate), Cr (creatinine), Cho (choline) and mI (myo-inositol) metabolites ratios. We used analysis of variance to compare metabolite ratios between the different patient groups previously defined.
Results: We found significant differences (p ≤ 0,05) between groups in NAA/Cho concentration (p=0,022), both in long and in short eco times and frontal and parietal anatomical regions. No other significant differences between groups were found.
Conclusion: MR spectroscopy could increase efficiency in Alzheimer’s disease premature diagnosis as well as turning out to be a useful additional tool for the clinician next to clinical history.

18
Feb 2014
POSTED BY
DISCUSSION 0 Comments

ECR 2013 Rec: Comparison of contrast-enhanced dual-energy mammography (CEDEM) with contrast-enhanced magnetic resonance imaging (CE-MRI) in breast lesions: a prototype report #SS1802a #B0951

ECR2013Rec_Blog_Cover_B0951_SS1802a

B-0951 Comparison of contrast-enhanced dual-energy mammography (CEDEM) with contrast-enhanced magnetic resonance imaging (CE-MRI) in breast lesions: a prototype report

T. Knogler, R. Leithner, M. Hörnig, M. Waitzbauer, F. Semturs, G. Langs, P. Homolka, K. Pinker-Domenig, T.H. Helbich | Monday, March 11, 14:00 – 15:30 / Room F1

Purpose: To test the feasibility of CEDEM, by comparing its results with CE-MRI in breast lesions.
Methods and Materials: Fifteen female patients with 15 breast lesions were included in this study. CEDEM was performed with a Mammomat Inspiration prototype (Siemens, Germany) before and after i.v. administration of 2 ml Iomeron® 400 (Bracco, Italy) per kg b.w. at a rate of 3.5ml/sec. The same lesions were assessed with CE-MRI (Tim Trio, Siemens, Erlangen, Germany) using a standard protocol and the administration of 0.2mmol Dotarem® (Guerbet, France) per kg b.w. Images of both modalities were assessed by two readers with respect to morphology and enhancement characteristics. A histological work-up was performed in all lesions.
Results: Histopathology revealed eight malignant and seven benign lesions (size range from 8 to 38mm). Morphology and enhancement characteristics were similar and comparable with both techniques. All malignant lesions showed strong contrast uptake and suspicious morphologic signs, whereas benign lesions tend to enhance less strong on both techniques. Based on the morphologic and enhancement characteristics CEDEM and CE-MRI allowed accurate differentiation of benign and malignant breast lesions.
Conclusion: CEDEM allows adequate differentiation of benign and malignant breast lesions using morphologic and enhancement characteristics. CEDEM imaging features are comparable to those of CE-MRI. CEDEM offers a feasible and low cost alternative to CE-MRI in breast lesions.

17
Feb 2014
POSTED BY
DISCUSSION 0 Comments

ECR 2013 Rec: Clinical feasibility of contrast-enhanced dual-energy mammography (CEDEM) with a tungsten (W)/titanium (Ti) anode/filter combination: a prototype report #SS1802a #B0950

ECR2013Rec_Blog_Cover_B0950_SS1802a

B-0950 Clinical feasibility of contrast-enhanced dual-energy mammography (CEDEM) with a tungsten (W)/titanium (Ti) anode/filter combination: a prototype report

T. Knogler, R. Leithner, M. Hörnig, F. Semturs, M. Waitzbauer, G. Langs, P. Homolka, K. Pinker-Domenig, T.H. Helbich | Monday, March 11, 14:00 – 15:30 / Room F1

Purpose: To test the feasibility of CEDEM with a W/Ti anode/filter combination for high energy images in a clinical setting.
Methods and Materials: Fifteen female patients with 15 breast lesions were included in this study. CEDEM was performed with a Mammomat Inspiration prototype (Siemens, Germany) before and after i.v. administration of 2-ml Iomeron® 400 (Bracco, Italy) per kg b.w. at a rate of 3.5ml/sec. Dual-energy images were acquired with 28-32kVp and a W/Rhodium (Rh) anode/filter combination for low-energy and 49 kVp and a W/Ti anode filter combination for high energy. Weighted subtraction images were computed for diagnostic work-up. Images were assessed by two readers with respect to lesion-enhancement and image quality. A histological work-up was performed in all lesions.
Results: Histopathology revealed eight malignant lesions and seven benign lesions (size range from 8 to 38mm). All malignant lesions enhanced and were seen from both readers on weighted subtraction images. Benign lesions did not enhance thus they were not visualised on weighted subtraction images. Image quality was rated excellent from both readers. Based on the visibility of the lesion CEDEM allowed an accurate differentiation of benign and malignant breast lesions.
Conclusion: CEDEM with a W/Ti anode/filter combination is suitable and feasible. Lesion visibility and image quality were excellent. Further research is needed to determine the value of CEDEM in a clinical setting.